Bituthene® 2P Elastomeric Liquid Detailing Membrane
BITUTHENE Liquid Membrane (E) — Part A and Part B: two component detailing compound designed for use with Bituthene 3000 Sheet Membrane. When cured BITUTHENE Liquid Membrane (E) forms a tough seamless rubber-like waterproofing for penetrations, laps, and other critical detail areas.
Installation
- Temperature - Only apply BITUTHENE® Liquid Membrane (E) in dry weather and when air temperatures are between 5°C and 40°C.
Substrate Preparation
Surfaces must be structurally sound and free of voids, spalled areas, loose aggregate and sharp protrusions. Repair concrete defects such as spalled or poorly consolidated areas and remove sharp protrusions. Remove contaminants such as grease, oil and wax from exposed surfaces. Remove dust, dirt, loose stone and debris. Concrete must be properly cured (minimum 7-days for normal structural concrete and 14-days for lightweight structural concrete) and shall be dry to <5% moisture content. Substrate temperature shall be between 5°C and 45°C. PREPRUFE® and BITUTHENE® membrane surfaces shall be clean, dry and undamaged.
Mixing
BITUTHENE® Liquid Membrane (E) pack is supplied in a single can containing Part A base with the Part B reactor located separately under the can lid. Using a slow speed mixer, pre-mix part A then, add Part B (clear) to Part A (black). Mix the two parts for approximately 1 minute at 100 rpm. Mix for a further 2-3 minutes at 200-300 rpm until uniform blending is achieved. Scrape the sides and bottom of the container during mixing to ensure thorough blending. At ambient temperatures below +10°C, store overnight at +20°C to improve blending and workability. Clean tools and equipment before BITUTHENE® LM (E) liquid membrane has cured.
Application
When used as a stand alone system, BITUTHENE Liquid Membrane (E) are mixed and applied in accordance with manufacturer’s instructions with a trowel or float, solid barrel gun or hand held squeegee to achieve a minimum thickness of 1.5mm. Apply to a minimum thickness of 2.5mm when used as a detailing aid with BITUTHENE® or PREPRUFE® membranes.
Once mixed BITUTHENE® Liquid Membrane (E) should be applied within 30mins to one hour. Material thickens quicker as the ambient temperature increases, which thickened material must be discarded. BITUTHENE® Liquid Membrane (E) shall be allowed to cure for 24 hours before being overlapped by BITUTHENE® or PREPRUFE® Membranes.
A minimum overlap of the BITUTHENE® sheet membrane of 50 mm shall be provided and where applicable between 50 mm and 75 mm onto PREPRUFE® sheet membranes.
BITUTHENE® Liquid Membrane (E) is designed to adhere to clean, dry concrete and metal substrates.
BITUTHENE® Liquid Membrane (E) application should be sequenced as detailed in any drawings or installation instructions for BITUTHENE® and PREPRUFE® waterproofing membranes.
UV Protection
BITUTHENE® Liquid Membrane (E) is not designed for permanently exposed applications. It is required that concrete must be poured within 56 days (or 42 days in hot climates) of application.
SUPPLY
- 5.7 litre pack (Parts A & B)
- Shelf Life 12 months